XA11 - Adapter for Pipettes calibration 11 ml for XA.4Y.M, XA.4Y.M.A.I Stazioni
search
  • XA11 - Adapter for Pipettes calibration 11 ml for XA.4Y.M, XA.4Y.M.A.I Stazioni

XA11 - Adapter for Pipettes calibration 11 ml for XA.4Y.M, XA.4Y.M.A.I Stazioni

1.960,00 €
IVA esclusa
XA11 adapter enables precise pipette calibration via gravimetric method using XA microbalances. Kit includes base, weighing pan, vessel, evaporation ring (reduces liquid evaporation), and glass chamber with dosing opening. Ensures centric loading and minimizes air drafts. Vessel capacity: 11ml. Complies with ISO 8655 standards. Ideal for XA.4Y.M and XA.4Y.M.A.I stations. Optimized for accuracy and repeatability in lab settings.
Quantità

 

Condizioni di vendita (Terms and conditions)

Our privacy policy

Our Privacy Policy explains our principles when it comes to the collection, processing, and storage of your information. This policy specifically explains how we employ cookies, as well as the options you have to control them.

  • 1 What are cookies?

    Cookies are small pieces of data, stored in text files that are stored on your computer or other device when websites are loaded in a browser. They are widely used to "remember" you and your preferences, either for a single visit or for multiple repeat visits

  • 2 How we use cookies

    We use cookies for a number of different purposes. Some cookies are necessary for technical reasons; some enable a personalized experience for both visitors and registered users; and some allow the display of advertising from selected third party networks.

  • 3 Controlling Cookies

    Visitors may wish to restrict the use of cookies or completely prevent them from being set. If you disable cookies, please be aware that some of the features of our service may not function correctly

  • 4 Information We Collect

    We only collect information about you if we have a reason to do so-for example, to provide our services, to communicate with you, or to make our services better.

We are committed to maintaining the trust and confidence of our website visitors. We do not collect, sell, rent or trade email lists or any data with other companies and businesses. Have a look at our Privacy Policy page to read detail information on when and why we collect your personal information, how we use it, the limited conditions under which we may disclose it to others and how we keep it secure.

We may change Cookies and Privacy policy from time to time. This policy is effective from 24th May 2018.

Descrizione prodotto


XA11 - Adapter for Pipettes calibration 11 ml for XA.4Y.M; XA.4Y.M.A.I Stazioni
XA11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means of a gravimetric method using the XA microbalance.
Set content:
  • base
  • weighing pan
  • weighing vessel
  • evaporation ring
  • glass chamber with an opening for dosing
Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped.
An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts.

Vessel capacity: 11 ml
Adapters for pipettes calibration
Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table presents the minimum reguirements in accordance with ISO 8655 standard. It also enables to select suitable adapter for pipette calibration and respective balance version.
Selected volume1 of apparatus under test
V
Resolution
mg
Repeatability and linearity
mg
Recommended balance
1 µl = V = 10 µl 0.001 0.002 MYA 21.5Y XA 6/21.5Y.M.A
XA 6/21.5Y.M
10 µl < V = 100 µl 0.01 0.02 XA 82/220.5Y.A
XA 82/220.5Y
XA 120/250.5Y.A
XA 120/250.5Y
100 µl < V = 1000 µl 0.1 0.2
1 ml < V = 10 ml 0.1 0.2
Adapter for pipette calibration MY 11 XA 11 XA 17 XA 100 XA 17 XA 100
Maximum vessel capacity 11 ml 11 ml 17 ml 100 ml 17 ml 100 ml
Weighing vessel mass ~10 g ~10 g ~11 g ~65 g ~11 g ~65 g

1 For practical purposes, the nominal volume may be used to choose the balance. [Reference: ISO8655-6:2002, pg. 2]
If the standard uncertainty of measurement of the balance is known (e.g. from the balance calibration certificate), it may be used instead of the repeatability and linearity. The standard uncertainty of measurement shall not be more than two to three times the resolution. [Reference: ISO8655-6:2002, pg. 2]


MNT-G6391